A limited number of studies that focused on instrumentation of the CTJ are available in literature, most of them being in vitro biomechanical studies. Both C7 and Th1, despite being part of cervical subaxial and thoracic spine respectively, differ from other vertebrae, thus requiring specific and tailored techniques for their instrumentation. In addition, the biomechanical stress provided by the transitional characteristics of the CTJ demands critical thinking on optimal extent of the arthrodesis area in an effort to prevent failure of instrumentation and adjacent segment diseases. Despite technical advances, instrumentation of the CTJ remains challenging and carries significant complication rates. We focused our attention on few specific issues and pitfalls, namely C7 and Th1 instrumentation techniques and rods design, need for crossing CTJ in posterior constructs and role of spinal navigation.
Challenges and pitfalls of C7 and Th1 instrumentation
C7 is a transitional vertebra with unique anatomical characteristics that differs from other subaxial and upper thoracic vertebrae[11]. This peculiar anatomy resides in the gradual anatomical changes between the mobile cervical spine and the stiff thoracic spine. From C5 to Th3 pedicles increase in diameter and dimension of LM gradually decrease from C3 to C7 resulting in their gradual conversion to transverse processes[29]. Current options in C7 fixation are PS (Fig.2), LM screws (Fig.3), trans-facet screws and trans-laminar screws (Fig.4)[2].
Even though it remains challenging, PS are more feasible in C7 than in other subaxial vertebrae. PS have shown to provide the highest biomechanical stability in posterior C7 fixation[13, 29] therefore should always be considered, especially in multilevel constructs, in cases with no anterior support or in osteoporotic patients[16]. Additionally, PS should be considered in thoracic constructs ending at C7 because of the great biomechanical forces implied in these cases on the upper instrumented vertebra. The most used insertion technique, as proposed by Lee et al.[33] consists in an entry point 1.6mm lateral and 2.5mm superior to the center of LM with an approximately 7° cranial trajectory. In order to provide additional safety to the procedure, Clifton et al.[8] proposed a direct palpation of the pedicle with a small angled blunt dissector through a small laminotomy in order to be aware of how much medial angulation is needed in screw insertion.
In our series PS, whenever feasible, were the instrumentation technique of choice for C7, used for 23 out of 36 cases (63,9%). In 10 cases C7 was left uninstrumented because it was judged to be too hazardous because of the anatomical changes by the underlying pathology. We have observed no screws loosening or pull-out complications at latest follow-up. This finding is consistent with the high biomechanical stability of PS reported in literature.
LM fixation of C7, despite being more challenging than other subaxial vertebrae, represents a valuable option. Several techniques are available for LM fixation. According to the technique proposed by Roy-Camille[36] the entry point is at the center of the LM and screw trajectory has to be perpendicular to the LM cortex with a 10° lateral angulation. Magerl[25] subsequently proposed a modified technique with an entry point slightly medial and cranial to the midpoint of LM and the screw trajectory parallel to the adjacent facet joint plane with a 20-30° of lateral angulation. This technique resulted in higher screw strength secondary to the longer screw purchase[42] with lower rates of facet joint violation but higher risks of nerve injury[19]. More recently Riew[16] proposed a modification of the technique by setting the entry point 1mm medial and 1mm caudal to the midpoint of the LM with a cranial and lateral angulation of screw trajectory aiming at the upper and outer corner of the LM. This technique has been proposed with the aim of simplification of the previous techniques by making screw trajectories easier to follow avoiding the need to intraoperatively guess at angles.
As general rule for LM screws, cranial angulation helps to reduce inferior facet joint violation. The lower the entry point is in the LM, the more cranial must be the screw trajectory to avoid facet violation[44]. At C7 due to the peculiar anatomy of the LM, screw trajectory must be more oblique than in other subaxial vertebrae. Presurgical knowledge of vertebral artery position is of critical importance to avoid unexpected vascular damage; at C7 level, the vertebral artery usually runs anterior to the LM thus being exposed to damage in case of bicortical LM screws.
In our cohort LM screws in C7 were used in only 3 cases (8.3%) in which pedicle screws were judged to be too hazardous either due to anatomic characteristic or to pedicle involvement by the primary pathology. In all of these cases screws were placed according to Magerl’s technique[25] because, in our opinion, this technique is safer and provides higher bone purchase[36].
Other techniques are available and may be used mostly as salvage techniques. C7 intralaminar screws are an effective alternative, providing a fixation biomechanically similar to LM screws[21] (Fig.4).
Trans-articular trans-facet screws have been described as a salvage technique or as an isolated facet joint fusion technique[1]. They provide provide stronger pull-out resistance because of the 4 cortical layers of bone purchase, risks are vertebral artery injury and facet fractures[1]. Two insertion techniques, proposed by Takayasu[43] and Dal Canto[9] are the most popular (Fig.4).
For Th1, as for other upper thoracic vertebrae, pedicle screws are the most stable posterior fixation technique providing a three-columns support with improved rotational strength compared to techniques of fixation involving only posterior columns[4, 35]. From C7 to Th2 the entry point for pedicle screws becomes more medial and the trajectory less angulated toward the midline[29].
In our series, we routinely placed pedicle screws in Th1 and upper thoracic vertebrae with an entry point 2-3mm inferior to the junction between the superior margin of the transverse process and the lateral margin of the superior articular process (Fig. 5). At Th1 level, medial angulation is usually between 20° and 25° medial but the correct trajectory should always be planned on a preoperative CT. The trajectory of the pedicle screw can then be either straight forward or anatomical following the anatomic plane of the pedicle[34] (Fig.5). In our surgical series, Th1 was always instrumented with PS except for 3 cases (8.4%) in which the vertebra was skipped because of pedicle involvement by primary pathology.
Upper thoracic instrumentation techniques other than PS mostly provide fixation only in posterior vertebral elements but can be useful alternatives. Trans-laminar screws may be placed with the same technique described above for C7 instrumentation providing a biomechanically effective alternative to PS in the upper thoracic region[37]. Posterior fixation in the costotransverse joint is another salvage technique option [49] (Fig.5). This technique is relatively easy and safe but the fixation provided is low[35].
Rods constructs
The connection of cervical and thoracic screws represents a specific challenge of posterior fixation across the CTJ as both have usually different screw head sizes and alignment problems may arise secondary to the different entry points and insertion techniques. The most commonly used technique is to connect two separate rods (usually 3.2-4 mm for cervical and 5.5-6 mm for thoracic) by means of lateral connectors (or dominos) or end-to-end connectors. Lateral connectors and end-to-end connectors provide the same biomechanical stiffness[48]. A more recent option are transitional dual-diameter rods. These rods present two different parts of different diameters designed to connect cervical and thoracic screws with a single bar[30]. Different diameters rods with lateral connectors are usually easier to implant because cervical and thoracic screw heads are frequently not perfectly in line.
Godzik et al.[18] found a small evidence that lateral connectors constructs provide lower biomechanical stability compared to continuous rods. Eleraky et al.[14] conversely found no differences between lateral connectors and single rod constructs. Significant differences in biomechanical stability between lateral connectors constructs and single diameter rods, whether small rods or dual diameter rods still need to be clarified. At present, there are no biomechanical studies that compared lateral connectors constructs to transitional dual diameter rods. Yang et al.[50] in an in vivo retrospective study found no differences in pseudoarthrosis rates between single diameter small rods (3.2 and 3.5 mm) and mixed constructs. In the same study, transitional constructs were however associated with longer operative time and higher intraoperative blood loss.
We believe that the use of transitional dual diameter rods is the more elegant and probably the most effective technique even if this remains to be scientifically demonstrated. We used single diameter rods in 22 cases (61.1%), most of these were small rods from a cervical set used because patients required minimal extension of the construct in the thoracic spine.
Ending at C7 or extend to Th1?
While for thoracic constructs the choice to stop at Th1 or Th2 as upper instrumented vertebra[10] is generally accepted, the need for crossing the CTJ in posterior cervical constructs is still debated. At today there are only few published studies that may guide surgeons in this decision making. A hypothesized protective effect of the extension of the construct across the CTJ is thought to rely on a more rigidity provided by inclusion of the thoracic spine. Conversely, a construct ending at C7 make the involved cervical segments act as a single column leaning over the rigid thoracic spine with only a single interposed disc, thus subjected to significant mechanical stress that may result in early disc degeneration[24]. In a biomechanical study Cheng et al.[7] reported that in posterior cervical instrumentations, the intradiscal pressure of the lower adjacent disc was significantly lower for instrumentations that crossed the CTJ. The published ‘in vivo’ studies however provide contrasting evidences. Articles by Schroeder et al.[41], Ibaseta et al.[24] and Fayed et al.[15] found that posterior cervical constructs ending at C7, have increased risks of adjacent segment disease, while Huang et al.[22] and Lee et al.[32] found no significant increase in adjacent segment disease when stopping the construct at C7. At the same time, instrumentations that cross the CTJ have been reported to be associated with increased operative times and intraoperative blood loss[15, 22].
On the basis of the available evidences, we think that the extent of instrumentation should be tailored to the individual patient. For instance, a young patient with long life expectancy may have a higher risk of developing ASD and reasonably has a low risk of complications secondary to longer operative times and increased blood loss thus, for this kind of patients the inclusion of CTJ may be indicated. On the other hand, an elderly patient may not have enough time (intended as life expectancy) to develop an ASD but will likelihood suffer complications from prolonged duration of surgery, therefore not extending the construct below C7 may be a good choice.
Spinal navigation
Since its introduction, spinal navigation has been increasingly used in vertebral instrumentation, particularly for PS placement. Screw placement has been historically guided by anatomical landmarks, 2D-Fluoroscopy was later developed in order to increase safety and accuracy[46]. 3D-Nav techniques have been subsequently developed increasing precision of the navigation. CT guided navigation (CT-Nav) or imageless navigation guided by intraoperative 3D C-Arm acquisition (3D-Fluoronav) are the most widely used navigation techniques[46]. Recently 3D-printed guides, made from a preoperative low-dose CT scan have been introduced with the aim of accuracy’s improvement and radiations’ reduction[6]. Both CT-Nav and 3D-Fluoronav have shown superiority compared to 2D-Fluoroscopy in terms of pedicle screw accuracy with 3D-Fluoronav that seem superior to CT-Nav[12, 45]. It is of note that superiority of 3D navigation techniques is more relevant in presence of vertebral deformity[45].
The lower cervical and upper thoracic spine represent a challenging zone for conventional intraoperative fluoroscopic visualization, because they are frequently obscured by shoulders[26]. Thus, especially at the CTJ, navigation is a useful tool that helps surgeons increase safety of instrumentation. Several papers have reported the high levels of accuracy provided by CT navigated pedicle screws placement at the CTJ[38, 40].
Our surgical cohort allows to compare between methods almost in equal proportions (CT-Nav, 3D-Fluoronav and 2D-Fluoroscopy). The limited sample size and our still growing experience with 3D navigation techniques due to their relative recent standardization, probably explain the non-superiority of one technique above the other. As mentioned before, we have found a small but significant superiority of 2D-Nav and 3D-Fluoronav compared to CT-Nav when comparing optimal screw placement (GR: A) and non-optimal screw placement (GR:B+C+D+E) (Tab.4). This might be explained by our relative lack of experience in the use of O-Arm that may lead to higher rates of minimal cortical violation during screw placement. We have not placed PS in complete free-hand technique without any intraoperative imaging assistance. We tend to strongly discourage this technique especially in a difficult anatomical region as the CTJ because it carries unnecessary risks that can no longer be justified in the present times. However, knowledge of anatomical landmarks and free-hand techniques are still mandatory and spine surgeons should not attempt procedures with the aid of navigation without being able to perform the same procedure without navigation.
Limitations
Our study carries the limitations of a retrospective observational surgical cohort study.
Despite our results are in line with what reported in literature, the small sample might have prevented us to find statistically significant differences between subgroups.