1.1The general information of site supervision during 2011–2020
From 2011 to 2020, there were 68, 75, 81, 82, 87, 80, 33, 57, 85 and 87 HIV screening laboratories conducted site supervision respectively, of which 60(88.24%), 74(98.67%), 76(93.83%), 81(98.78%), 60(68.97%), 51(63.75%), 23(69.70%), 41(71.93%), 59(69.41%) and 60(68.97%) had excellent results. During 2011–2020, the laboratory participated site supervision covered the whole province included 173 districts and counties. Among them, 25 regions had more than 7 times of site supervision, such as Xichang, Meishan, Xuzhou, Lizhou, Jingyang. There were 11 areas had not been assessed, such as the area of Jinniu, the Qingbaijiang, Wenjiang, Xinjin, Dayi. (Fig. 2)
B. The distribution Map of frequency of site supervision, 2011–2020
C. The distribution Map of HIV screening laboratory in 2011
D. The distribution Map of HIV screening laboratory in 2020
Note
The map in this figure is designed by using the ArcMap 10.6 software.
During 2011–2020, perform site supervision institution covered hospitals, CDC, maternal and child care center, blood donation and supply institutions and the judiciary. The proportion of site supervision in hospital and CDC had increased gradually, and institution with higher frequency of supervision was in hospitals and CDC. The specific distribution is shown in Fig. 3.
Note
2017 and 2018 were two years to complete a round of site supervision, so the numbers differed significantly from other years
1.2 AID/HIV screening laboratory scores of each region in Sichuan province during 2011–2020
The average scores of 21 cities in the past 10 years were analyzed and it can be seen that there was no significant difference in the laboratory conditions of cities before 2015. But the overall scores of laboratories in all regions in 2015 were fluctuated than 2015 before. And the scores of Chengdu, Zigong, Panzhihua, Nanchong, Aba and Ganzi have obvious fluctuations (Table 1).
Table 1
The average score of cities in Sichuan
|
2011
|
2012
|
2013
|
2014
|
2015
|
2016
|
2017
|
2018
|
2019
|
2020
|
Chengdu
|
96.28
|
97.89
|
95.38
|
97
|
88.96
|
87.17
|
/
|
90.8
|
93
|
85.7
|
Zigong
|
96.7
|
95.33
|
93.33
|
83.33
|
95.33
|
92.5
|
/
|
92.13
|
90.5
|
86.67
|
Panzhihua
|
94.62
|
97.33
|
96
|
99
|
92
|
96
|
/
|
95.83
|
94.5
|
89.67
|
Luzhou
|
98.63
|
96.75
|
87
|
93.63
|
88
|
83
|
/
|
86.25
|
94.25
|
95
|
Deyang
|
97.3
|
94.33
|
98
|
98.33
|
92.83
|
90.9
|
/
|
96.5
|
90.13
|
95.17
|
Mianyang
|
95.68
|
98
|
98.08
|
98.17
|
97.92
|
97.8
|
/
|
96
|
95.6
|
98.83
|
Guangyuan
|
95.83
|
96.5
|
95.25
|
97.25
|
93.5
|
87.17
|
/
|
92.75
|
89
|
95.63
|
Suining
|
98.33
|
97.25
|
96
|
98
|
90.88
|
79.5
|
/
|
97.33
|
97.13
|
93.38
|
Neijiang
|
97.63
|
97.17
|
98.25
|
97.25
|
91.1
|
86.42
|
/
|
92
|
91.67
|
94.5
|
Leshan
|
92.73
|
95.25
|
91
|
96.83
|
96.6
|
90.2
|
/
|
93.2
|
93.5
|
92.5
|
Nanchong
|
98.9
|
96.67
|
97
|
97.67
|
79.25
|
87.33
|
/
|
93.88
|
92.33
|
85.75
|
Meishan
|
92.77
|
93.67
|
95.67
|
96.5
|
90.75
|
91.33
|
/
|
78.88
|
93.5
|
95.17
|
Yibin
|
93.73
|
96.67
|
94.8
|
97
|
86.71
|
86.5
|
92.67
|
/
|
92
|
91.25
|
Guangan
|
96.7
|
98
|
96.5
|
94
|
95.25
|
80.67
|
93.32
|
/
|
93.63
|
94.5
|
Dazhou
|
96.67
|
97.33
|
95.67
|
96.75
|
94.75
|
96.25
|
90.75
|
/
|
93.5
|
93.33
|
Yaan
|
90.8
|
96.38
|
84.83
|
96.67
|
84
|
89.17
|
/
|
93
|
90.67
|
93
|
Bazhong
|
90
|
97
|
93.75
|
97.25
|
96.25
|
91.33
|
/
|
92.13
|
93.38
|
91.5
|
Ziyang
|
94.87
|
98.13
|
97.67
|
96.67
|
93
|
86.33
|
/
|
92.38
|
92.5
|
93.67
|
Aba
|
95.37
|
91
|
96
|
98
|
81.75
|
75.5
|
92.97
|
/
|
88.5
|
85.5
|
Ganzi
|
81.25
|
97.33
|
94
|
96.75
|
89
|
89.75
|
86.17
|
/
|
92.33
|
83.33
|
Liangshan
|
93.33
|
97
|
96
|
97.25
|
83.5
|
78.1
|
85.5
|
83.63
|
83.33
|
88.68
|
Note: ”/” the site supervision mode of 2017–2018 was a round involved two years. |
1.3 The analysis of excellence rate of different institutions during 2011–2020
Through the analysis of the excellence rate of different types of assessment laboratories from 2011 to 2020, it was found that the excellence rate of each institution was relatively stable during 2011–2014, while the overall score of each regional laboratory in 2015 fluctuated significantly than 2015 before and all of excellent rate has declined (Table 2).
Table 2
The excellence rate of site supervised laboratories in different institution types, 2011–2020
|
2011
|
2012
|
2013
|
2014
|
2015
|
2016
|
2017
|
2018
|
2019
|
2020
|
Average
|
Hospital
|
83.87
|
100.00
|
90.48
|
97.56
|
64.58
|
52.50
|
55.56
|
70.83
|
64.00
|
53.06
|
73.24
|
Maternal and child care centre
|
100.00
|
100.00
|
100.00
|
100.00
|
44.44
|
54.55
|
100.00
|
50.00
|
80.00
|
85.71
|
81.47
|
CDC
|
90.63
|
96.43
|
96.97
|
100.00
|
82.14
|
75.00
|
57.14
|
92.86
|
69.57
|
79.31
|
84.00
|
Others
|
100.00
|
100.00
|
100.00
|
100.00
|
100.00
|
100.00
|
/
|
100.00
|
100.00
|
0.00
|
88.89
|
ALL
|
88.24
|
98.67
|
93.83
|
98.78
|
68.97
|
61.25
|
60.00
|
73.47
|
68.24
|
63.22
|
77.47
|
1.4 The analysis of factors affecting excellence rate in screening laboratory
Of all studied variables, multivariate logistic regression analysis found that the following variables were significant influencing factors of laboratory quality, including staffing(OR = 3.12, 95% CI = 1.31–7.45), laboratory SOP and management (OR = 0.39, 95% CI = 0.18–0.86), periodic calibration of equipment (OR = 0.35, 95%CI = 0.14–0.86), standardization of HIV testing (OR = 0.07, 95%CI = 0.02–0.21), uniqueness of sample number(OR = 0.31, 95%CI = 0.11–0.89), standardized use of quality control materials (OR = 0.15, 95%CI = 0.06–0.36), standard drawing of quality control chart (OR = 0.21, 95%CI = 0.09–0.49), biosafety facilities (OR = 0.44, 95%CI = 0.21–0.94) ( Table 3).
Table 3
The influence factors of operation quality of 461 HIV screening laboratory in Sichuan
Item
|
The number of excellent
|
The rate of excellent(%)
|
Total
|
OR
|
AOR
|
Building time
|
|
|
|
|
|
2010 year and before
|
380
|
81.54
|
466
|
1
|
1
|
2011 yearand after
|
206
|
76.58
|
269
|
0.74(0.51 ~ 1.07)*
|
0.74(0.35 ~ 1.56)
|
Staffing
|
|
|
|
|
|
At least 5 people
|
375
|
77.16
|
486
|
1
|
1
|
6 or more people
|
211
|
84.74
|
249
|
1.64(1.10 ~ 2.46)**
|
3.12(1.31 ~ 7.45)**
|
HIV laboratory personnel are qualified
|
|
|
|
Conformity
|
584
|
79.67
|
733
|
1
|
|
non-conformity
|
2
|
1
|
2
|
1
|
|
The actual operators are qualified
|
|
|
|
Conformity
|
582
|
80.39
|
724
|
1
|
1
|
non-conformity
|
4
|
36.36
|
11
|
0.14(0.04 ~ 0.48)**
|
0.31(0.03 ~ 3030)
|
Data archive
|
|
|
|
|
|
Conformity
|
523
|
81.21
|
644
|
1
|
1
|
non-conformity
|
63
|
69.23
|
91
|
0.52(0.32 ~ 0.85)**
|
0.46(0.17 ~ 1.26)*
|
Laboratory SOP and management
|
|
|
|
Conformity
|
359
|
81.04
|
443
|
1
|
1
|
non-conformity
|
167
|
74.55
|
224
|
0.69(0.47 ~ 1.01)*
|
0.39(0.18 ~ 0.86)**
|
without judgement
|
60
|
88.24
|
68
|
|
|
Quality control and on-site evaluation of HIV testing sites in the jurisdiction
|
|
Conformity
|
290
|
68.08
|
426
|
1
|
|
non-conformity
|
5
|
83.33
|
6
|
2.29(0.27 ~ 19.82)
|
|
without judgement
|
291
|
95.1
|
306
|
|
|
Standardization of laboratory network information filling
|
|
|
Conformity
|
401
|
86.24
|
465
|
1
|
1
|
non-conformity
|
10
|
66.67
|
15
|
0.32(0.11 ~ 0.96)**
|
0.42(0.09 ~ 2.08)
|
without judgement
|
175
|
68.63
|
255
|
|
|
Review the correctness of HIV laboratory test data in the jurisdiction
|
|
Conformity
|
58
|
69.05
|
84
|
1
|
|
non-conformity
|
2
|
66.67
|
3
|
0.90(0.08 ~ 10.33)
|
|
without judgement
|
526
|
81.17
|
648
|
|
|
Normal operation of equipment and relevant records
|
|
|
Conformity
|
483
|
80.5
|
600
|
1
|
|
non-conformity
|
103
|
76.3
|
135
|
0.78(0.50 ~ 1.22)
|
|
Thermostatic facilities
|
|
|
|
|
Conformity
|
497
|
79.14
|
628
|
1
|
|
non-conformity
|
29
|
74.36
|
39
|
0.76(0.36 ~ 1.61)
|
|
without judgement
|
60
|
88.24
|
68
|
|
|
Periodic calibration of equipment
|
|
|
|
Conformity
|
519
|
82.12
|
632
|
1
|
1
|
non-conformity
|
67
|
65.05
|
103
|
0.40(0.26 ~ 0.63)***
|
0.35(0.14 ~ 0.86)**
|
Standardization of HIV testing
|
|
|
|
|
Conformity
|
254
|
95.49
|
266
|
1
|
1
|
non-conformity
|
332
|
70.79
|
469
|
0.11(0.06 ~ 0.21)***
|
0.07(0.02 ~ 0.21)***
|
Standardization of HIV screening report
|
|
|
|
Conformity
|
536
|
79.41
|
675
|
1
|
|
non-conformity
|
50
|
83.33
|
60
|
1.35(0.69 ~ 2.65)
|
|
Standardization of HIV retest test sheet
|
|
|
|
Conformity
|
529
|
79.31
|
667
|
1
|
|
non-conformity
|
57
|
83.82
|
68
|
1.34(0.69 ~ 2.63)
|
|
Uniqueness of HIV sample number
|
|
|
|
Conformity
|
471
|
80.1
|
588
|
1
|
1
|
non-conformity
|
55
|
69.62
|
79
|
0.57(0.33 ~ 0.96)**
|
0.31(0.11 ~ 0.89)**
|
without judgement
|
60
|
88.24
|
68
|
|
|
Outer quality control
|
|
|
|
|
Conformity
|
352
|
72.58
|
485
|
1
|
|
non-conformity
|
19
|
76
|
25
|
1.20(0.47 ~ 3.06)
|
|
without judgement
|
215
|
95.56
|
225
|
|
|
Standardized use of quality control materials
|
|
|
Conformity
|
436
|
81.19
|
537
|
1
|
1
|
non-conformity
|
74
|
63.25
|
117
|
0.39(0.26 ~ 0.62)***
|
0.15(0.06 ~ 0.36)***
|
without judgement
|
76
|
93.83
|
81
|
|
|
Standard drawing of quality control chart
|
|
|
|
Conformity
|
482
|
83.1
|
580
|
1
|
1
|
non-conformity
|
104
|
67.1
|
155
|
0.42(0.28 ~ 0.62)***
|
0.21(0.09 ~ 0.49)***
|
Correct analysis of quality control
|
|
|
|
Conformity
|
512
|
79.63
|
643
|
1
|
|
non-conformity
|
74
|
80.43
|
92
|
1.05(0.61 ~ 1.82)
|
|
Quality control of rapid dignosis
|
|
|
|
Conformity
|
332
|
74.11
|
448
|
1
|
|
non-conformity
|
44
|
69.84
|
63
|
0.81(0.45 ~ 1.44)
|
|
without judgement
|
210
|
93.75
|
224
|
|
|
Laboratory area and personal protective equipment
|
|
|
Conformity
|
432
|
79.85
|
541
|
1
|
1
|
non-conformity
|
94
|
74.6
|
126
|
0.74(0.47 ~ 1.17)*
|
0.83(0.28 ~ 2.41)
|
without judgement
|
60
|
88.24
|
68
|
|
|
Biosafety facilities
|
|
|
|
|
Conformity
|
415
|
81.21
|
511
|
1
|
1
|
non-conformity
|
171
|
76.34
|
224
|
0.75(0.51 ~ 1.09)*
|
0.44(0.21 ~ 0.94)**
|
Batch inspection
|
|
|
|
|
|
Conformity
|
447
|
76.41
|
585
|
1
|
|
non-conformity
|
5
|
71.43
|
7
|
0.77(0.15 ~ 4.02)
|
|
without judgement
|
134
|
93.71
|
143
|
|
|
Batch inspection with reagents used
|
|
|
|
Conformity
|
444
|
76.55
|
580
|
1
|
|
non-conformity
|
8
|
66.67
|
12
|
0.61(0.18 ~ 2.07)
|
|
without judgement
|
134
|
93.71
|
143
|
|
|
Storage and use records of reagents
|
|
|
|
Conformity
|
540
|
80.12
|
674
|
1
|
|
non-conformity
|
46
|
75.41
|
61
|
0.76(0.41 ~ 1.40)
|
|
Note: *P value < 0.2, **P value < 0.05, ***P value < 0.001. |
Item which without judgement: these were not required to site supervision in 2011 included uniqueness of HIV sample number, thermostatic facilities, laboratory area and personal protective equipment. Standardized use of quality control materials, batch inspection and batch inspection with reagents used were not required to site supervision during 2011–2012. Item both outer quality control and quality control of rapid diagnosis were not asked to site supervision in 2011–2013. Laboratory SOP and management and quality control and on-site evaluation of HIV testing sites in the jurisdiction were not required to site supervision before 2015. Item both Standardization of laboratory network information filling and review the correctness of HIV laboratory test data in the jurisdiction were not judged because Laboratory network information system was shut down during 2016–2019.