A variety of preoperative markers for GGNs prior to VATS have been reported, including hook wire[4, 13], coil[14, 15], methyl blue[16], 99mTc[17], hydrogel plugs[18], barium[8, 9], and fiducial marker[8, 19]. Because of its high feasibility and usability, hook wire is the most widely used marker in preoperative localization. Although the preoperative hook wire localization has a high success rate, the reported probability of hook wire localization failure is 7.5% owing to migration or dislodgement[4, 9]. At present, there are few articles on the analysis of localization failure[11]. Therefore, the purpose of this article was to clarify the factors of localization failure to provide clinical decision-making in advance.
In this study, 21 out of 372 patients showed localization failure with an incidence rate of 5.65%, which is similar to that reported in the literature[9]. Among the failed cases, 13 developed pneumothorax during the positioning process. As the pneumothorax progresses, the tip of the guide wire protrudes out of the lung parenchyma, and the hook wire cannot be released to the target nodule. Among the 21 failed cases, 13 showed pneumothorax before the guide wire was released successfully during the localization process. As the pneumothorax progresses, the guide wire tip protrudes out of the pleural cavity and the hook wire cannot be released to the target nodule. Even if the positioning is reinitiated, it is difficult to fix the guide needle to the ideal position within the calculated distance given the pneumothorax, which causes the swing of the pleural cavity. Usually, when pneumothorax occurs, the depth of localization is longer than the predetermined distance given the retraction of the lung tissue. However, it is difficult for the doctor to insert the guide needle excessively beyond the predetermined distance during operation to avoid damage to large blood vessels and cause severe haemoptysis. The remaining eight failed cases of dislodgement were found with pneumothorax during CT reconfirmation (five cases) and VATS (three cases) after the initial successful localization.
In our study, the incidence of pneumothorax formation is 39.52%, which is within the range of 12.8–68.1% reported in the literature[11]. In this study, 85.7% of localization failure cases were related to pneumothorax (P < 0.001 compared with the control group). The results of multiple regression analysis also confirmed that pneumothorax was the independent factor related to localization failure. Literature reports show that trans-fissure is an important influencing factor of localization failure[10, 11]. In our results, trans-fissure showed a significant difference in the univariate logistic analysis. It is an important influencing factor rather than an independent factor, which is different from the literature reports. Because the trans-fissure approach has to penetrate three layers of pleura, the incidence of pneumothorax with the trans-fissure approach is higher than that with the traditional approach. We speculate that the trans-fissure approach is due to the occurrence of pneumothorax and leads to localization failure; hence, the trans-fissure is a risk factor for pneumothorax, not a direct risk factor for localization failure.
According to the results of univariate logistic regression, other factors such as depth of the nodule, trans-emphysema, and localization of multiple nodules are also related to the failure of localization. The shallower the location depth, the greater the risk of dislodgment after the occurrence of pneumothorax, because the tip of the hook wire is easily pulled out of the pulmonary parenchyma under the swing of the chest cavity. Previous studies have shown that the shallower depth threshold for hook wire placement is 1.8 cm[10], so as to possibly avoid pneumothorax. In our research, the localization depth of the failure group was shallower than that of the success group (15.52 ± 6.85 vs. 21.34 ± 9.17, p < 0.001). Although published studies have reported that it is safe and feasible to locate multiple nodules at the same time[20], our study found that the rate of failure was higher than that of the single nodule group (47.6% vs. 25.9%, p = 0.030). Simultaneous localization of multiple nodules is related to localization failure, which may increase the risk of localization failure. Emphysema, especially trans-emphysema or pulmonary bullae in the puncture path, is the influencing factor of localization failure according to the results of our univariate logistic regression analysis. Therefore, the pre-localization plan should attempt to avoid emphysema in the lung parenchyma.
Other reported factors of localization are the location of the nodule in the lower lobe[21], surgical history[21], vital capacity[11, 22], physician experience[11], and location time[10, 23]. These factors are mainly related to the formation of pneumothorax and whether they are related to localization failure still requires further investigation. The results of multiple regression analysis in this study indicate that only pneumothorax is an independent risk factor. This could be because the tail of the hook wire is fixed on the chest wall and the hook tip that is placed on the target nodule can move relative to each other with the formation and progression of pneumothorax. The formation of pneumothorax can drag the hook wire that has been fixed to the target nodule. The hook wire tip may be displaced or pulled off into the chest cavity, resulting in failure of localization.
The limitation of this article is that the sample size of the failure group is quite small, which maybe affect the results of statistical analysis, and there is no comparison and inclusion of other commonly used metal markers to analyse the causes of failure, such as Coil.
In conclusion, although the preoperative localization success rate of GGNs under CT guidance is high, localization failure still exists. Pneumothorax is an independent risk factor for failure in the localization process.