1 Kizer, J. R. & Devereux, R. B. Patent foramen ovale in young adults with unexplained stroke. New England Journal of Medicine353, 2361-2372 (2005).
2 Saver, J. L. Cryptogenic stroke. New England Journal of Medicine374, 2065-2074 (2016).
3 Messe, S. R. & Kasner, S. E. Patent foramen ovale in cryptogenic stroke: not to close. Circulation118, 1999-2004 (2008).
4 Mas, J.-L. et al. Patent foramen ovale closure or anticoagulation vs. antiplatelets after stroke. New England Journal of Medicine377, 1011-1021 (2017).
5 Saver, J. L. et al. Long-term outcomes of patent foramen ovale closure or medical therapy after stroke. New England Journal of Medicine377, 1022-1032 (2017).
6 Søndergaard, L. et al. Patent foramen ovale closure or antiplatelet therapy for cryptogenic stroke. New England Journal of Medicine377, 1033-1042 (2017).
7 Lee, P. H. et al. Cryptogenic stroke and high-risk patent foramen ovale: the DEFENSE-PFO trial. Journal of the American College of Cardiology71, 2335-2342 (2018).
8 Pinto, F. When and how to diagnose patent foramen ovale. Heart91, 438-440 (2005).
9 Pearson, A. C., Labovitz, A. J., Tatineni, S. & Gomez, C. R. Superiority of transesophageal echocardiography in detecting cardiac source of embolism in patients with cerebral ischemia of uncertain etiology. Journal of the American College of Cardiology17, 66-72 (1991).
10 Job, F. P. et al. Comparison of transcranial contrast Doppler sonography and transesophageal contrast echocardiography for the detection of patent foramen ovale in young stroke patients. The American journal of cardiology74, 381-384 (1994).
11 Nemec, J. J. et al. Comparison of transcranial Doppler ultrasound and transesophageal contrast echocardiography in the detection of interatrial right-to-left shunts. The American journal of cardiology68, 1498-1502 (1991).
12 Di Tullio, M. et al. Comparison of diagnostic techniques for the detection of a patent foramen ovale in stroke patients. Stroke24, 1020-1024 (1993).
13 Jauss, M., Kaps, M., Keberle, M., Haberbosch, W. & Dorndorf, W. A comparison of transesophageal echocardiography and transcranial Doppler sonography with contrast medium for detection of patent foramen ovale. Stroke25, 1265-1267 (1994).
14 Van, H. et al. Sensitivity of transcranial Doppler versus intracardiac echocardiography in the detection of right-to-left shunt. JACC: Cardiovascular Imaging3, 343-348 (2010).
15 Seidel, G., Kaps, M. & Gerriets, T. Potential and limitations of transcranial color-coded sonography in stroke patients. Stroke26, 2061-2066 (1995).
16 Itoh, T. et al. Rate of successful recording of blood flow signals in the middle cerebral artery using transcranial Doppler sonography. Stroke24, 1192-1195 (1993).
17 Lien, L. M. et al. Comparison of transcranial color‐coded sonography and magnetic resonance angiography in acute ischemic stroke. Journal of Neuroimaging11, 363-368 (2001).
18 Kwon, J. H., Kim, J. S., Kang, D. W., Bae, K. S. & Kwon, S. U. The thickness and texture of temporal bone in brain CT predict acoustic window failure of transcranial Doppler. Journal of Neuroimaging16, 347-352 (2006).
19 Kim, B. J., Kim, N.-Y., Kang, D.-W., Kim, J. S. & Kwon, S. U. Provoked right-to-left shunt in patent foramen ovale associates with ischemic stroke in posterior circulation. Stroke45, 3707-3710 (2014).
20 Del Sette, M. et al. Diagnosis of right-to-left shunt with transcranial Doppler and vertebrobasilar recording. Stroke38, 2254-2256 (2007).
21 Perren, F., Kremer, C., Iwanovski, P., Savva, E. & Landis, T. Detection of Right‐to‐Left Cardiac Shunt in the Absence of Transcranial Acoustic Bone. Journal of Neuroimaging26, 269-272 (2016).
22 Guo, Y.-Z. et al. Comparison of vertebral artery and middle cerebral artery monitoring for right-to-left shunt detection by contrast-enhanced transcranial Doppler. Scientific reports6, 1-6 (2016).
23 Kobayashi, K. et al. Right‐to‐Left‐Shunt Detected by c‐TCD Using the Orbital Window in Comparison with Temporal Bone Windows. Journal of Neuroimaging22, 80-84 (2012).
24 Trattnig, S., Schwaighofer, B., Hübsch, P., Schwarz, M. & Kainberger, F. Color‐coded Doppler sonography of vertebral arteries. Journal of ultrasound in medicine10, 221-226 (1991).
25 Chuang, Y.-M., Chan, L., Wu, H.-M., Lee, S.-P. & Chu, Y.-T. The clinical relevance of vertebral artery hypoplasia. Acta Neurol Taiwan21, 1-7 (2012).
26 Agustin, S. J. U. et al. Effects of posture on right-to-left shunt detection by contrast transcranial doppler. Stroke42, 2201-2205 (2011).
27 Wu, C.-T. et al. Effects of patient position on right-to-left shunt detection by contrast transcranial Doppler. Ultrasound in medicine & biology41, 654-658 (2015).
28 Topcuoglu, M. A. Diagnosis of right-to-left shunts by transcranial doppler in patients with insufficient temporal bone window. Stroke39, e123-e124 (2008).
29 Zarrinkoob, L. et al. Blood flow distribution in cerebral arteries. Journal of Cerebral Blood Flow & Metabolism35, 648-654 (2015).
30 Furlan, A. J. et al. Closure or medical therapy for cryptogenic stroke with patent foramen ovale. New England Journal of Medicine366, 991-999 (2012).
31 Meier, B. et al. Percutaneous closure of patent foramen ovale in cryptogenic embolism. New England Journal of Medicine368, 1083-1091 (2013).
32 Carroll, J. D. et al. Closure of patent foramen ovale versus medical therapy after cryptogenic stroke. New England Journal of Medicine368, 1092-1100 (2013).
33 Jauss, M. & Zanette, E. Detection of right-to-left shunt with ultrasound contrast agent and transcranial Doppler sonography. Cerebrovascular diseases10, 490-496 (2000).
34 Spencer, M. P. et al. Power m‐mode transcranial Doppler for diagnosis of patent foramen ovale and assessing transcatheter closure. Journal of Neuroimaging14, 342-349 (2004).